Table Of Contents

UDP Read (UDP Read Text (String Address)) (G Dataflow)

Version:
    Last Modified: March 20, 2017

    Reads a datagram string from a UDP socket.

    This node returns data when it receives any bytes, and waits the full timeout ms only if it receives no bytes.

    Programming Patterns
    connector_pane_image
    datatype_icon

    connection ID

    A network connection refnum that uniquely identifies the UDP socket.

    datatype_icon

    max size

    The maximum number of bytes to read. If you wire a value other than 548 to this input, Windows might return an error because the node cannot read fewer bytes than are in a packet.

    Default: 548

    datatype_icon

    timeout ms

    Time, in milliseconds, that the node waits to complete before reporting a timeout error. A value of -1 indicates to wait indefinitely.

    Default: 25,000 ms

    datatype_icon

    error in

    Error conditions that occur before this node runs. The node responds to this input according to standard error behavior.

    Default: No error

    datatype_icon

    connection ID out

    Same value as connection ID.

    datatype_icon

    data out

    The data read from the UDP datagram.

    datatype_icon

    error out

    Error information. The node produces this output according to standard error behavior.

    datatype_icon

    port

    The port of the UDP socket that sent the datagram.

    datatype_icon

    address

    The address of the computer where a datagram originates.