Table Of Contents

Synchronize Timed Structure Starts (G Dataflow)

Version:
    Last Modified: March 8, 2017

    Synchronizes the start of Timed Loops or Timed Sequence structures you enter in timed structure names by adding the names to the synchronization group you specify in synchronization group name.

    All timed structures in a synchronization group wait until all the structures are ready to execute.

    Programming Patterns
    connector_pane_image
    datatype_icon

    clear

    If True, removes all timed structures from synchronization group name before adding the timed structures in timed structure names to the group. Set clear to True to remove any timed structures that do not correspond to a Timed Loop. The default is False.

    datatype_icon

    replace

    Replaces the timed structures in synchronization group name with the timed structures you enter in timed structure names. If replace is FALSE and the timing source is a member of another hierarchy, the node returns an error.

    datatype_icon

    synchronization group name

    Is the name for the group of timed structures you want to synchronize.

    datatype_icon

    timeout ms

    Time, in milliseconds, that a timed structure waits on other members of the synchronization group to arrive at the synchronization point. If any of the timed structures in the group do not arrive in time, the timed structure returns an error. The default is 10000 ms. A value of -1 indicates to wait indefinitely.

    datatype_icon

    timed structure names

    Names of the timed structures you want to synchronize. By default, the node deletes the timed structure from its current group and adds it to the group you specify in synchronization group name. If you set replace to FALSE and a timed structure you specify in timed structure names is a member of another group, the node returns an error to indicate that it could not add the timed structure to the synchronization group.

    datatype_icon

    error in

    Error conditions that occur before this node runs. The node responds to this input according to standard error behavior.

    Default: No error

    datatype_icon

    timed structures names out

    Names of all timed structures in the group after LabVIEW adds the names to the synchronization group you specify.

    datatype_icon

    error out

    Error information. The node produces this output according to standard error behavior.

    Where This Node Can Run:

    Desktop OS: Windows

    FPGA: Not supported