Table Of Contents

Pattern Generator (Ramp Pattern by Increment) (G Dataflow)

Version:
    Last Modified: January 9, 2017

    Generates a signal containing a ramp pattern with a specific interval between samples.

    connector_pane_image
    datatype_icon

    start

    First value of the ramp. This node does not impose conditions on the relationship between start and end. Therefore, this node can generate ramp-up and ramp-down patterns.

    Default: 0

    datatype_icon

    end

    Final value of the ramp. This node does not impose conditions on the relationship between start and end. Therefore, this node can generate ramp-up and ramp-down patterns.

    Default: 1

    datatype_icon

    increment

    Interval between two adjacent samples in the ramp pattern.

    The value of increment must meet the following conditions:

    • Must not be 0.
    • Must be positive if start is less than end.
    • Must be negative if start is greater than end.

    Default: 0.01

    datatype_icon

    error in

    Error conditions that occur before this node runs. The node responds to this input according to standard error behavior.

    Default: No error

    datatype_icon

    dt

    Sampling rate in samples per second.

    This input is available only if you configure this node to return a waveform.

    Default: 0.1

    datatype_icon

    ramp pattern

    Output ramp pattern.

    This output returns a waveform or an array of double-precision, floating point numbers.

    datatype_icon

    samples

    The number of samples in the ramp pattern.

    datatype_icon

    error out

    Error information. The node produces this output according to standard error behavior.

    Where This Node Can Run:

    Desktop OS: Windows

    FPGA: Not supported