Table Of Contents

Pattern Generator (Impulse) (G Dataflow)

Version:
    Last Modified: January 9, 2017

    Generates a signal containing an impulse pattern.

    connector_pane_image
    datatype_icon

    amplitude

    Amplitude of the pattern.

    Default: 1

    datatype_icon

    delay

    Index within the pattern at which the impulse occurs. This input must be greater than or equal to 0. If this input is less than 0 or greater than or equal to the number of samples, this node sets the output pattern to 0 and returns an error.

    Default: 0

    datatype_icon

    error in

    Error conditions that occur before this node runs. The node responds to this input according to standard error behavior.

    Default: No error

    datatype_icon

    samples

    Number of samples in the pattern. This input must be greater than delay. If this input is negative or zero, the node sets the output pattern to an empty array and returns an error.

    Default: 128

    datatype_icon

    impulse pattern

    Output impulse pattern.

    datatype_icon

    error out

    Error information. The node produces this output according to standard error behavior.

    Algorithm for Generating the Impulse Pattern

    If the sequence X represents the impulse pattern, this node generates the pattern according to the following equation:

    x i = { A if i = d 0 elsewhere

    for i = 0, 1, 2, ..., n - 1

    where

    • A is the amplitude
    • d is the delay
    • n is the number of samples

    Where This Node Can Run:

    Desktop OS: Windows

    FPGA: Not supported