Table Of Contents

Create Timing Source (Create Software-Triggered Timing Source) (G Dataflow)

Last Modified: March 8, 2017

Creates a software-triggered timing source you can use to control the execution of a timed structure. The timing source does not start until the first timed structure that uses the timing source starts.

Programming Patterns
connector_pane_image
datatype_icon

trigger ID

The numeric identifier of the software-triggered timing source. The valid range of trigger ID values is 0-127. Because this input is an integer rather than a string, it is safe to use this node in time-critical code.

datatype_icon

error in

Error conditions that occur before this node runs. The node responds to this input according to standard error behavior.

Default: No error

datatype_icon

timing source name

The name of the timing source created by the node.

datatype_icon

error out

Error information. The node produces this output according to standard error behavior.

Where This Node Can Run:

Desktop OS: Windows

FPGA: Not supported