Table Of Contents

MT Get Complex IQ Component (G Dataflow)

Last Modified: January 9, 2017

Extracts the desired component from the IQ (complex) in parameter.

I, Q, magnitude, and phase data are available for extraction from the IQ (complex) in parameter. This node returns a complex envelope in the CE component parameter that contains the t0, dt, and Y values for the chosen component.

connector_pane_image
datatype_icon

IQ data in

The baseband (downconverted) time-domain data.

datatype_icon

t0

The trigger (start) time of the acquired signal.

Default: 0.0

datatype_icon

dt

Time interval between data points in the acquired signal.

Default: 1.0

datatype_icon

Y

The complex-valued time-domain data array. The real and imaginary parts of this complex data array correspond to the in-phase (I) and quadrature-phase (Q) data, respectively.

datatype_icon

component choice

The complex envelope data component to extract from the complex envelope contained in the IQ Data (complex) in parameter.

spd-note-note
Note  

If you do not request phase data, phase continuity is not preserved.

Name Description
I

Extracts the in-phase component.

Q

Extracts the quadrature component.

Magnitude

Extracts the magnitude of signal.

Phase

Extracts the phase of the signal.

Default: I

datatype_icon

error in

Error conditions that occur before this node runs. The node responds to this input according to standard error behavior.

Default: no error

datatype_icon

reset?

A Boolean that determines whether initialization of an internal node state tracks the ending phase.

TRUE The node clears the state information about each call.
FALSE The node uses the final phase from the previous call as the starting phase for the next call, ensuring phase continuity between calls.

Default: FALSE

datatype_icon

IQ data out

The baseband (downconverted) time-domain data. This node does not modify this data, so this parameter is identical to the IQ data in parameter.

datatype_icon

t0

The trigger (start) time of the acquired signal.

datatype_icon

dt

Time interval between data points in the acquired signal. The I/Q sampling rate is the reciprocal of this value.

datatype_icon

Y

The complex-valued time-domain data array. The real and imaginary parts of this complex data array correspond to the in-phase (I) and quadrature-phase (Q) data, respectively.

datatype_icon

CE component

The complex envelope data component selected in the component choice parameter. Wire this parameter to a LabVIEW waveform graph to display the selected component as a function of time.

datatype_icon

error out

Error information. The node produces this output according to standard error behavior.

Where This Node Can Run:

Desktop OS: Windows

FPGA: Not supported