Table Of Contents

MT Measure ASK Quadrature Impairments (G Dataflow)

Last Modified: January 9, 2017

Calculates and reports amplitude-shift keying (ASK) quadrature impairments on a symbol-by-symbol basis at the symbol timing.

spd-note-note
Note  

Certain measurements like I/Q gain imbalance and quadrature skew are not applicable for the ASK modulation format because of the inherently one-dimensional nature of the ASK constellation.

connector_pane_image
datatype_icon

recovered complex waveform

The time-aligned and oversampled complex waveform data after matched filtering, frequency offset correction, and phase offset correction. Wire the output complex waveform parameter of MT Demodulate ASK to this parameter.

datatype_icon

t0

Trigger (start) time of the Y array.

Default: 0.0

datatype_icon

dt

Time interval between data points in the Y array.

Default: 1.0

datatype_icon

Y

The complex-valued signal-only baseband modulated waveform. The real and imaginary parts of this complex data array correspond to the in-phase (I) and quadrature-phase (Q) data, respectively.

datatype_icon

input bit stream

The demodulated bit stream from the output bit stream parameter of MT Demodulate ASK.

datatype_icon

impairment measurement window

The window over which impairments are measured.

datatype_icon

start index

Index of the first sample of the measurement window.

Default: 0

datatype_icon

width

Number of symbols over which to measure impairments. A value of -1 (default) measures impairments over all symbols. Positive values must be two or greater.

Default: -1

datatype_icon

error in

Error conditions that occur before this node runs. The node responds to this input according to standard error behavior.

Default: no error

datatype_icon

reset?

A Boolean that determines how the node handles bits from partial symbols in the input bit stream.

TRUE Discards bits making up incomplete symbols.
FALSE Saves the leftover bits and starts with them on the next iteration.

Default: TRUE

datatype_icon

ASK system parameters

Parameter values defining the ASK system. Wire the ASK system parameters cluster of MT Generate ASK System Parameters (M) or MT Generate ASK System Parameters (map) to this cluster. Do not alter the values.

datatype_icon

samples per symbol

An even number of samples dedicated to each symbol. Multiply this value by the symbol rate to determine the sample rate.

spd-note-note
Note  

The demodulation and detector nodes use timing recovery, which is optimized for four or more samples per symbol.

Default: 16

datatype_icon

symbol map

An ordered array that maps each symbol to its desired level. The number of ASK levels in the array is 2 N , where N is the number of bits per symbol. The vector length for the symbols farthest from the origin is 1.

datatype_icon

magnitude error

The measured magnitude error as a percentage. Magnitude error is the magnitude difference between the ideal and the actual measured symbol locations.

datatype_icon

RMS measurement

The RMS impairment value calculated over the impairment measurement window.

datatype_icon

peak measurement

The peak impairment value measured over the impairment measurement window.

datatype_icon

peak symbol index

Index of the symbol having the peak magnitude of impairment.

datatype_icon

individual symbol measurements

The impairment value for each individual symbol.

datatype_icon

DC offset measurements

The measured DC offset of the I or Q waveforms as a percentage of the largest I and Q value in the symbol map of the recovered complex waveform.

datatype_icon

I

The DC offset of the I waveform, expressed as a percentage of the largest I or Q value in the symbol map.

datatype_icon

Q

The DC offset of the Q waveform, expressed as a percentage of the largest I or Q value in the symbol map.

datatype_icon

origin offset

The offset, in dB, of the constellation origin from its ideal location.

datatype_icon

phase error

The measured phase error in degrees. Notice that the phase offset is removed by the demodulator and is excluded from this measurement.

datatype_icon

RMS measurement

The RMS impairment value calculated over the impairment measurement window.

datatype_icon

peak measurement

The peak impairment value measured over the impairment measurement window.

datatype_icon

peak symbol index

Index of the symbol having the peak magnitude of impairment.

datatype_icon

individual symbol measurements

The impairment value for each individual symbol.

datatype_icon

EVM

The measured error vector magnitude (EVM) expressed as a percentage.

datatype_icon

RMS measurement

The RMS impairment value calculated over the impairment measurement window.

datatype_icon

peak measurement

The peak impairment value measured over the impairment measurement window.

datatype_icon

peak symbol index

Index of the symbol having the peak magnitude of impairment.

datatype_icon

individual symbol measurements

The impairment value for each individual symbol.

datatype_icon

modulation error ratio

The measured modulation error ratio in dB.

datatype_icon

error out

Error information. The node produces this output according to standard error behavior.

Where This Node Can Run:

Desktop OS: Windows

FPGA: Not supported


Recently Viewed Topics