Home > Support > NI Product Manuals > LabVIEW Communications System Design Suite 1.0 Manual

Writes a string or an array of strings as lines to a file.

connector_pane_image
datatype_icon

prompt

Custom message that appears in the title bar of the file dialog box that appears when you do not wire a value to file path.

datatype_icon

file path

The file to which you want to write data.

This input can be a reference to a file or an absolute file path. In both cases, the node creates the specified file if it does not already exist. The node opens the specified file without requiring you to call Open/Create/Replace File first.

Default: No value — Displays a file dialog box that prompts you to select a file.

datatype_icon

text

String or array of strings that this node writes to a file.

datatype_icon

error in

Error conditions that occur before this node runs. The node responds to this input according to standard error behavior.

Default: no error

datatype_icon

refnum out

A reference to the file that this node uses.

datatype_icon

cancelled?

Boolean specifying whether you cancelled the dialog box that appears if you did not wire an input file to this node.

TRUE You cancelled the dialog box.
FALSE You did not cancel the dialog box or the dialog box did not appear.
datatype_icon

error out

Error information. The node produces this output according to standard error behavior.