    Generates an array containing a sinusoidal pattern.

    connector_pane_image
    datatype_icon

    samples

    Number of samples of the sinusoidal pattern. samples greater than or equal to 0. The default is 128. If samples is less than zero, the VI sets sinusoidal pattern to an empty array and returns an error.

    datatype_icon

    amplitude

    Amplitude of sinusoidal pattern.

    Default: 1.0

    datatype_icon

    phase

    The phase of the sine wave without reset and in degrees. phase must be in degrees rather than radians. If phase is in radians, convert the value to degrees before using this node.

    Default: 0.0

    datatype_icon

    cycles

    Number of complete periods of the sinusoidal pattern. The default value is 1.0.

    Note  

    Because cycles is a floating-point number, fractional cycles are possible for the sinusoidal pattern. Furthermore, setting cycles to a negative number does not generate an error condition because it is mathematically correct and useful to consider negative frequencies in Fourier and spectral analysis.

    datatype_icon

    sinusoidal pattern

    An array containing a sinusoidal pattern of samples. The largest sinusoidal pattern the VI can generate depends on the amount of memory in your system and is theoretically limited to 2,147,483,647 (231 - 1) elements.

    datatype_icon

    error