Home > Support > NI Product Manuals > LabVIEW Communications System Design Suite 1.0 Manual
Version:

    Creates a new NI-Sync instrument driver session.

    connector_pane_image
    datatype_icon

    resource name

    The resource name of the module to initialize. The resource name is assigned in NI Measurement & Automation Explorer (MAX).

    Syntax

    PXI[bus number]::device number

    Optional fields are shown in square brackets. VISA aliases are also valid as the resource name.

    datatype_icon

    reset device

    A Boolean that specifies whether to reset the NI-Sync module during the initialization procedure. The default is FALSE.

    TRUE The NI-Sync module is reset during the initialization procedure.
    FALSE The NI-Sync module is not reset during the initialization procedure.

    Default: FALSE

    datatype_icon

    error in

    Error conditions that occur before this node runs. The node responds to this input according to standard error behavior.

    Default: no error

    datatype_icon

    instrument handle out

    The instrument handle that you obtain from the niSync Initialize node.

    datatype_icon

    error out

    Error information. The node produces this output according to standard error behavior.