Home > Support > NI Product Manuals > LabVIEW Communications System Design Suite 1.0 Manual

Converts polar coordinates to rectangular coordinates. You must specify the phase of the polar coordinates in pi radians, which use fewer FPGA resources than radians. To convert a radian value to pi radians, multiply the value by pi.

connector_pane_image
datatype_icon

magnitude

Magnitude.

This input supports only the fixed-point data type.

datatype_icon

phase

Phase in pi radians, which use fewer FPGA resources than radians.

Tip  

If you have a value in radians, multiply that value by pi before wiring the value to this terminal.

This input supports only the fixed-point data type.

datatype_icon

input valid

A Boolean that specifies whether the next data point has arrived for processing. Wire the output valid output of an upstream node to this input to transfer data from the upstream node to this node.

TRUE The data point is valid and can be processed.
FALSE The data point is not valid.
datatype_icon

ready for output

A Boolean that specifies whether downstream nodes are ready for this node to return a new value. Use a Feedback Node to wire the ready for input output of a downstream node to this input of the current node.

TRUE The downstream node is ready for the next data point.
FALSE The downstream node is not ready for the next data point.
Note  

If this terminal is FALSE during a given cycle, the output valid terminal returns FALSE during that cycle.

Default: TRUE

datatype_icon

x

X value of the rectangular coordinates.

datatype_icon

y

Y value of the rectangular coordinates.

datatype_icon

output valid

A Boolean that indicates whether this node has computed a result that downstream nodes can use. Wire this output to the input valid input of a downstream node to transfer data from the node to the downstream node.

TRUE The node has computed a result that downstream nodes can use.
FALSE The node has not computed a result that downstream nodes can use.
datatype_icon

ready for input

A Boolean that indicates whether this node is ready to accept new input data. Use a Feedback Node to wire this output to the ready for output input of an upstream node.

TRUE The node is ready to accept new input data.
FALSE The node is not ready to accept new input data.
Note  

If this terminal returns FALSE during a given cycle, LabVIEW discards any data that other nodes send to this node during the following cycle. LabVIEW discards this data even if the input valid terminal is TRUE during the following cycle.