Home > Support > NI Product Manuals > LabVIEW Communications System Design Suite 1.0 Manual

Sets/gets the configuration values for the Synchronization library by connecting to the Register Bus.

Input Parameters

  • register instruction specifies a read or write register instruction. This parameter is usually obtained from the register instruction parameter of the Process node in the Register Bus FPGA library. The source of this parameter defines the instances of the Register Bus nodes to which the Synchronization node is wired and is communicated from the host.
  • sync.resources identifies the Synchronization instance. Obtain sync.resources from ni579x Create.

Output Parameters

  • read completion indicates whether the register read operation has completed, and returns the value for the register read.
  • ready for input indicates whether the node is ready to accept new input data in the next cycle. Use a Feedback Node to wire this parameter to the ready for output terminal of an upstream node.
connector_pane_image

Installed By: LabVIEW Communications System Design Suite (introduced in 1.0)

Where This Node Can Run:

Desktop OS: none

FPGA: All devices