Routes a signal in the adapter module from the specified source to the specified destination terminal.

Input Parameters

  • Register Bus—The Register Bus object created by ni579x Open node and used as the session handle for the NI-579x Configuration nodes.
  • source—The source signal. Valid values:
    • None—Disconnects route to destination.
    • LO1—The local oscillator.
    • LO In—The LO IN front-panel terminal.
    • Rx In—The RX IN front-panel terminal.
    • Tx Mixer Output—The output of the Tx mixer.
    • Tx I (Mixer Bypass)—The I component of the baseband Tx signal, bypassing the Tx Mixer.
    • Sample Clock—The signal used as the Sample Clock.
    • Reference Clock—The signal used as the Reference Clock for the Sample Clock and LO.
  • destination—The destination terminal. Valid values:
    • Rx Mixer Input—The modulation signal input to the Rx mixer.
    • Rx Mixer LO Input—The LO signal input to the Rx mixer.
    • Tx Mixer LO Input—The LO signal input to the Tx mixer.
    • Tx Out—The TX OUT front panel terminal.
    • LO Out—The LO OUT front panel terminal.
    • Clk Out—The CLK OUT front panel terminal.

Output Parameters

  • Register Bus (out) The Register Bus object created by ni579x Open and used as the session handle for the NI-579x Configuration nodes.
connector_pane_image

Installed By: LabVIEW Communications System Design Suite (introduced in 1.0)

Where This Node Can Run:

Desktop OS: Windows

FPGA: Not supported