CLIP Signal Name | Data Type | Control/Indicator | Description |
---|---|---|---|
Tx I | I16 | Control | 16-bit two's complement DAC data for transmit I channel. |
Tx Q | I16 | Control | 16-bit two's complement DAC data for receive Q channel. |
Initialization Done | Boolean | Indicator | Indicates whether the device is ready to use. |
PLL Locked | Boolean | Indicator | Indicates whether the phase-locked loop (PLL) is locked. This signal is valid only when using a Reference Clock, either through the CLK IN connector or through the Sync Clock or IoModSyncClock. |
LO Locked | Boolean | Indicator | Indicates whether the local oscillator (LO) is locked. |
User Command | U8 | Control | Configures the clocking, ADC, sampling, and other settings for your device. Use this signal in conjunction with the User Data 0 and User Data 1 signals to select values for these settings. Apply these settings by selecting the User Command Commit signal. Refer to the User Command Reference for information about values for this signal. |
User Command Commit | Boolean | Control | Applies the settings configured with the User Command signal. |
User Command Idle | Boolean | Indicator | Indicates whether the device is prepared to accept more commands from the User Command signal. |
User Data 0 | U8 | Control | Specifies configuration for the command in the User Command signal. Use the User Command, User Data 0, and User Data 1 signals to configure your device. Refer to the User Command Reference for information about values for this signal. |
User Data 1 | U8 | Control | Specifies configuration for the command in the User Command signal. Use the User Command, User Data 0, and User Data 1 signals to configure your device. Refer to the User Command Reference for information about values for this signal. |
User Command Status | U8 | Indicator | Indicates whether the previous command completed successfully. |
User Return | U16 | Indicator | Returns data configured by the User Command signal. |
User Error | U8 | Indicator | Indicates that an error occurred and you must reinitialize the device. |
DIO Port 0 Rd Data* | U8 | Indicator | Reads data through the AUX I/O connector on the DIO port channels <0..3>. For example, for DIO Port 0, bit 0 corresponds with DIO Port (0), bit 1 corresponds with DIO Port (1), and so on. The upper four bits of the U8 are unused. |
DIO Port 0 Wr Data* | U8 | Control | Writes data through the AUX I/O connector on the DIO port channels <0..3>. For example, for DIO Port 0, bit 0 corresponds with DIO Port (0), bit 1 corresponds with DIO Port (1), and so on. The upper four bits of the U8 are unused. |
DIO Port 0 WE Request* | Boolean | Configures the DIO port channels <0..3> on the AUX I/O connector for reading or writing. | |
DIO Port 1 Rd Data* | U8 | Indicator | Reads data through the AUX I/O connector on the DIO port channels <0..3>. For example, for DIO Port 0, bit 0 corresponds with DIO Port (0), bit 1 corresponds with DIO Port (1), and so on. The upper four bits of the U8 are unused. |
DIO Port 1 Wr Data* | U8 | Control | Writes data through the AUX I/O connector on the DIO port channels <0..3>. For example, for DIO Port 0, bit 0 corresponds with DIO Port (0), bit 1 corresponds with DIO Port (1), and so on. The upper four bits of the U8 are unused. |
DIO Port 1 WE Request* | Boolean | Control | Configures the DIO port channels <0..3> on the AUX I/O connector for reading or writing. |
PFI 0 Rd Data* | Boolean | Indicator | Reads data through the AUX I/O connector on the PFI line. |
PFI 0 Wr Data* | Boolean | Control | Writes data through the AUX I/O connector on the PFI line. |
PFI 0 WE* | Boolean | Control | Configures the PFI line on the AUX I/O connector for reading or writing. |
PFI 1 Rd Data* | Boolean | Indicator | Reads data through the AUX I/O connector on the PFI line. |
PFI 1 Wr Data* | Boolean | Control | Writes data through the AUX I/O connector on the PFI line. |
PFI 1 WE* | Boolean | Control | Configures the PFI line on the AUX I/O connector for reading or writing. |
PFI 2 Rd Data* | Boolean | Indicator | Reads data through the AUX I/O connector on the PFI line. |
PFI 2 Wr Data* | Boolean | Control | Writes data through the AUX I/O connector on the PFI line. |
PFI 2 WE* | Boolean | Control | Configures the PFI line on the AUX I/O connector for reading or writing. |
PFI 3 Rd Data* | Boolean | Indicator | Reads data through the AUX I/O connector on the PFI line. |
PFI 3 Wr Data* | Boolean | Control | Writes data through the AUX I/O connector on the PFI line. |
PFI 3 WE* | Boolean | Control | Configures the PFI line on the AUX I/O connector for reading or writing. |
Register Bus Idle | Boolean | Indicator | Indicates when the FAM Registers interface is being accessed. To use the Register Bus signals, wait for this signal to be TRUE. |
Register Bus Address | U32 | Control | Configures the FAM Registers interface address for read or write data. |
Register Bus Read Data | U16 | Indicator | Returns the FAM Registers interface data to read from a Register Bus address. |
Register Bus Read | Boolean | Control | Executes a Register Bus Read when this signal is on a FALSE-to-TRUE transition. |
Register Bus Write Data | U32 | Control | Configures the FAM Registers interface data to write to a Register Bus address. |
Register Bus Write | Boolean | Control | Executes a Register Bus Write when this signal is on a FALSE-to-TRUE transition. |
Synchronize DAC | Boolean | Control | Signal for the rising edge between DAC sync user commands. |