Home > Support > NI Product Manuals > LabVIEW Communications System Design Suite 1.0 Manual
Version:

    The following table shows the front panel connector and signal descriptions for the NI 5772.

    Caution  

    To avoid permanent damage to the NI 5772, disconnect all signals connected to the NI 5772 before powering down the module, and connect signals only after the adapter module has been powered on by the NI FlexRIO FPGA module.

    Table 1. NI 5772 Front Panel Connectors
    Device Front Panel Connector Signal Description
    REF IN External Reference Clock input, 50 Ω, single-ended.
    CLK IN External Sample Clock input, 50 Ω, single-ended.
    AI 0 Analog input channel 0, 50 Ω, single-ended.
    AI 1 Analog input channel 1, 50 Ω, single-ended.
    TRIG Trigger input and output channel.
    AUX I/O Refer to Table 3 for the signal list and descriptions.
    Caution  

    Connections that exceed any of the maximum ratings of any connector on the NI 5772R can damage the device and the chassis. NI is not liable for any damage resulting from such connections.

    For more detailed information about the NI 5772 front panel connectors, refer to the NI 5772R Specifications.