Home > Support > NI Product Manuals > LabVIEW Communications System Design Suite 1.0 Manual
Version:
    Number of channels 2
    Frequency range 400 MHz to 4.4 GHz
    Frequency step <1 kHz
    Gain range [1] 0 dB to 31.5 dB
    Gain step 0.5 dB
    Maximum input power (Pin) -15 dBm
    Noise figure 5 dB to 7 dB
    Frequency accuracy [2] 2.5 ppm
    Maximum instantaneous real-time bandwidth
    NI 2942R 40 MHz 40 MHz
    NI 2942R 120 MHz 120 MHz
    Maximum I/Q sample rate 200 MS/s
    Analog-to-digital converter (ADC)
    Resolution 14 bit
    sFDR 88 dB
    • 1 The received signal amplitude resulting from the gain setting varies over the frequency band and among devices.
    • 2 Frequency accuracy is based on temperature-compensated crystal oscillator (TCXO) vendor specifications and is not measured. Alternatively, you can incorporate an external reference source to provide a more precise frequency Reference Clock and to achieve better frequency accuracy.