Home > Support > NI Product Manuals > LabVIEW Communications System Design Suite 1.0 Manual
Version:
    Frequency range 400 MHz to 4.4 GHz
    Frequency step <1 kHz
    Maximum output power (Pout) 50 mW to 100 mW (17 dBm to 20 dBm)
    Gain range [1] 0 dB to 31 dB
    Gain step 0.5 dB
    Frequency accuracy [2] 2.5 ppm
    Maximum instantaneous real-time bandwidth [3]
    16-bit sample width 20 MHz
    8-bit sample width 40 MHz
    Maximum I/Q sampling rate [4]
    16-bit sample width 25 MS/s
    8-bit sample width 50 MS/s
    DAC 2 channels, 400 MS/s, 16 bit
    DAC SFDR 80 dB
    • 1 The output power resulting from the gain setting varies over the frequency band and among devices.
    • 2 Frequency accuracy is based on temperature-compensated crystal oscillator (TCXO) vendor specifications and is not measured. Alternatively, you can incorporate an external reference source to provide a more precise frequency reference clock and to achieve better frequency accuracy.
    • 3 Instantaneous bandwidth depends on many factors including, but not limited to, network configuration and host computer performance. Actual data throughput may be chip set dependent.
    • 4 I/Q sampling rate depends on many factors including, but not limited to, network configuration and host computer performance. Actual data throughput may be chip set dependent.