Home > Support > NI Product Manuals > LabVIEW Communications System Design Suite 1.0 Manual
Version:
    Frequency range 2.4 GHz to 2.5 GHz and 4.9 GHz to 5.9 GHz
    Frequency step <1 kHz
    Gain range [1] 0 dB to 92.5 dB
    Gain step 2 dB
    Maximum input power (Pin) -15 dBm
    Noise figure 5 dB to 7 dB
    Frequency accuracy [2] 2.5 ppm
    Maximum instantaneous real-time bandwidth [3]
    16-bit sample width 19 MHz
    8-bit sample width 36 MHz
    Maximum I/Q sample rate [4]
    16-bit sample width 25 MS/s
    8-bit sample width 50 MS/s
    Analog-to-digital converter (ADC) 2 channels, 100 MS/s, 14 bit
    ADC SFDR 88 dB
    • 1 The received signal amplitude resulting from the gain setting varies over the frequency band and among devices.
    • 2 Frequency accuracy is based on temperature-compensated crystal oscillator (TCXO) vendor specifications and is not measured. Alternatively, you can incorporate an external reference source to provide a more precise frequency Reference Clock and to achieve better frequency accuracy.
    • 3 Instantaneous bandwidth depends on many factors including, but not limited to, network configuration and host computer performance. Actual data throughput may be chipset dependent.
    • 4 I/Q sample rate depends on many factors including, but not limited to, network configuration and host computer performance. Actual data throughput may be chipset dependent.