Home > Support > NI Product Manuals > LabVIEW Communications System Design Suite 1.0 Manual
Version:
    Frequency range 50 MHz to 2.2 GHz
    Frequency step <1 kHz
    Maximum output power (Pout)
    50 MHz to 1.2 GHz 50 mW to 100 mW (17 dBm to 20 dBm)
    1.2 GHz to 2.2 GHz 30 mW to 70 mW (15 dBm to 18 dBm)
    Gain range [1] 0 dB to 31 dB
    Gain step 1.0 dB
    Frequency accuracy [2] 2.5 ppm
    Maximum instantaneous real-time bandwidth [3]
    16-bit sample width 20 MHz
    8-bit sample width 40 MHz
    Maximum I/Q sample rate [4]
    16-bit sample width 25 MS/s
    8-bit sample width 50 MS/s
    Digital-to-analog converter (DAC) 2 channels, 400 MS/s, 16 bit
    DAC spurious-free dynamic range (sFDR) 80 dB
    • 1 The output power resulting from the gain setting varies over the frequency band and among devices.
    • 2 Frequency accuracy is based on temperature-compensated crystal oscillator (TCXO) vendor specifications and is not measured. Alternatively, you can incorporate an external reference source to provide a more precise frequency Reference Clock and to achieve better frequency accuracy.
    • 3 Instantaneous bandwidth depends on many factors including, but not limited to, network configuration and host computer performance. Actual data throughput may be chipset dependent.
    • 4 I/Q sample rate depends on many factors including, but not limited to, network configuration and host computer performance. Actual data throughput may be chipset dependent.