Home > Support > NI Product Manuals > LabVIEW Communications System Design Suite 1.0 Manual
Version:
    Frequency range 70 MHz to 6 GHz
    Frequency step <1 kHz
    Gain range [1] 76 dB
    Gain step 1.0 dB
    Maximum input power (Pin) -15 dBm
    Noise figure 5 dB to 7 dB
    Frequency accuracy [2] ±2.0 ppm
    Maximum instantaneous real-time bandwidth 56 MHz
    Maximum I/Q sample rate [3]
    Single channel enabled 61.44 MS/s
    Two channels enabled 30.72 MS/s
    Analog-to-digital converter (ADC) [4] 12 bits
    • 1 The received signal amplitude resulting from the gain setting varies over the frequency band and among devices.
    • 2 Frequency accuracy is based on temperature-compensated crystal oscillator (TCXO) vendor specifications and is not measured. Alternatively, you can incorporate an external reference source to provide a more precise frequency Reference Clock and to achieve better frequency accuracy.
    • 3 I/Q sample rate depends on many factors including, but not limited to, USB connection and host computer performance. Actual data throughput may be chipset dependent.
    • 4 The ADC rate changes with the sample rate.