Home > Support > NI Product Manuals > LabVIEW Communications System Design Suite 1.0 Manual
Version:
    Maximum slot-to-slot skew 100 ps
    Accuracy ±25 ppm max (guaranteed over the operating temperature range)
    Maximum jitter 3 ps RMS phase-jitter (10 Hz to 12 kHz range), 2 ps RMS phase-jitter (12 kHz to 20 MHz range)
    Duty-factor for PXIe_CLK100 45% to 55%
    Absolute differential voltage (When terminated with a 50 Ω load to 1.30 V or Thévenin equivalent) 400 to 1000 mV
    Note  