Table Of Contents

IviUpconverter Create Frequency Power List [LST (G Dataflow)

Last Modified: October 24, 2017

Creates a named list of frequency and power value pairs.

connector_pane_image
datatype_icon

instrument handle

The instrument handle that you obtain from the IviUpconverter Initialize or IviUpconverter Initialize With Options Node. The handle identifies a particular instrument session.

Default: None

datatype_icon

error in

Error conditions that occur before this node runs.

The node responds to this input according to standard error behavior.

Standard Error Behavior

Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.

error in does not contain an error error in contains an error
If no error occurred before the node runs, the node begins execution normally.

If no error occurs while the node runs, it returns no error. If an error does occur while the node runs, it returns that error information as error out.

If an error occurred before the node runs, the node does not execute. Instead, it returns the error in value as error out.

Default: No error

datatype_icon

name ("")

Pass the name of the list. Default Value: ""

datatype_icon

frequency

Pass the array of frequency values to become elements of the list.

The array must have as many elements as the power.

Units: Hertz

datatype_icon

power

Pass the array of power values to become elements of the list.

The array must have as many elements as the frequency.

Units: dBm

datatype_icon

instrument handle out

The instrument handle that you obtain from the IviUpconverter Initialize or IviUpconverter Initialize With Options VI. The handle identifies a particular instrument session. Default Value: None

datatype_icon

error out

Error information.

The node produces this output according to standard error behavior.

Standard Error Behavior

Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.

error in does not contain an error error in contains an error
If no error occurred before the node runs, the node begins execution normally.

If no error occurs while the node runs, it returns no error. If an error does occur while the node runs, it returns that error information as error out.

If an error occurred before the node runs, the node does not execute. Instead, it returns the error in value as error out.

Where This Node Can Run:

Desktop OS: Windows