Table Of Contents

IviUpconverter Configure PM [PM] (G Dataflow)

Version:
    Last Modified: October 24, 2017

    Configures the modulation source and deviation for the upconverter's phase modulation.

    connector_pane_image
    datatype_icon

    instrument handle

    The instrument handle that you obtain from the IviUpconverter Initialize or IviUpconverter Initialize With Options Node. The handle identifies a particular instrument session.

    Default: None

    datatype_icon

    error in

    Error conditions that occur before this node runs.

    The node responds to this input according to standard error behavior.

    Standard Error Behavior

    Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.

    error in does not contain an error error in contains an error
    If no error occurred before the node runs, the node begins execution normally.

    If no error occurs while the node runs, it returns no error. If an error does occur while the node runs, it returns that error information as error out.

    If an error occurred before the node runs, the node does not execute. Instead, it returns the error in value as error out.

    Default: No error

    datatype_icon

    source ("")

    Pass the source of the signal that is used as the modulating signal. If more than one source is specified, the voltages of all sources are summed. Multiple source names are separated by commas. The driver uses this value to set the IviUpconverter PM Source [PM] property. Users who want to achieve interchangeability should use a virtual PM source name. The virtual PM source name should be sufficiently specific to the test system such that it is unlikely to conflict with a physical PM source name. Default Value: ""

    datatype_icon

    deviation (0.0 Radian)

    Pass the extent of modulation the upconverter applies to the RF output signal with the modulating signal as a result of summing all sources, internal and external. The driver uses this value to set the IviUpconverter PM Deviation [PM] property. Default Value: 0.0 Radian

    datatype_icon

    instrument handle out

    The instrument handle that you obtain from the IviUpconverter Initialize or IviUpconverter Initialize With Options VI. The handle identifies a particular instrument session. Default Value: None

    datatype_icon

    error out

    Error information.

    The node produces this output according to standard error behavior.

    Standard Error Behavior

    Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.

    error in does not contain an error error in contains an error
    If no error occurred before the node runs, the node begins execution normally.

    If no error occurs while the node runs, it returns no error. If an error does occur while the node runs, it returns that error information as error out.

    If an error occurred before the node runs, the node does not execute. Instead, it returns the error in value as error out.

    Where This Node Can Run:

    Desktop OS: Windows

    FPGA: Not supported

    Web Server: Not supported in VIs that run in a web application


    Recently Viewed Topics