IviUpconverter Configure IQ Impairment [IQI] (G Dataflow)

Version:
    Last Modified: October 24, 2017

    Configures the settings that simulate or correct impairment for the upconverter's IQ (vector) modulation.

    connector_pane_image
    datatype_icon

    instrument handle

    The instrument handle that you obtain from the IviUpconverter Initialize or IviUpconverter Initialize With Options Node. The handle identifies a particular instrument session.

    Default: None

    datatype_icon

    error in

    Error conditions that occur before this node runs.

    The node responds to this input according to standard error behavior.

    Standard Error Behavior

    Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.

    error in does not contain an error error in contains an error
    If no error occurred before the node runs, the node begins execution normally.

    If no error occurs while the node runs, it returns no error. If an error does occur while the node runs, it returns that error information as error out.

    If an error occurred before the node runs, the node does not execute. Instead, it returns the error in value as error out.

    Default: No error

    datatype_icon

    I offset

    Pass an origin offset voltage to the I signal.

    The range of allowable values is -100% to +100%. The driver uses this value to set the IviUpconverter IQ Impairment I Offset [IQI] property.

    Default Value: 0.0 %

    datatype_icon

    Q offset

    Pass the origin offset voltage to the Q signal.

    The range of allowable values is -100% to +100%. The driver uses this value to set the IviUpconverter IQ Impairment Q Offset [IQI] property.

    Default Value: 0.0 %

    datatype_icon

    ratio

    Pass the gain imbalance between the I and Q channels.

    For no imbalance this value is set to 0%. The driver uses this value to set the IviUpconverter IQ Impairment Ratio [IQI] property.

    Default Value: 0.0 %

    datatype_icon

    skew

    Pass the adjustment of the phase angle between the I and Q vectors.

    If this skew is zero, the phase angle is 90 degrees. The driver uses this value to set the IviUpconverter IQ Impairment Skew [IQI] property.

    Default Value: 0.0 Degree

    datatype_icon

    instrument handle out

    The instrument handle that you obtain from the IviUpconverter Initialize or IviUpconverter Initialize With Options VI. The handle identifies a particular instrument session. Default Value: None

    datatype_icon

    error out

    Error information.

    The node produces this output according to standard error behavior.

    Standard Error Behavior

    Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.

    error in does not contain an error error in contains an error
    If no error occurred before the node runs, the node begins execution normally.

    If no error occurs while the node runs, it returns no error. If an error does occur while the node runs, it returns that error information as error out.

    If an error occurred before the node runs, the node does not execute. Instead, it returns the error in value as error out.