    Configures the trigger source, pulse width, and gating enabled for the pulse generator within the RF signal generator.

    connector_pane_image
    datatype_icon

    pulse width (50.0e-6 seconds)

    Specifies the width of the output pulse. The driver uses this value to set the IviRFSigGen>>Pulse Generator>>Pulse Width property. Units: Seconds Default Value: 50.0e-6 seconds

    datatype_icon

    trigger source (Internal)

    Specifies the source of the signal the pulse generator uses to generate one pulse. The driver uses this value to set the IviRFSigGen>>Pulse Generator>>Pulse Trigger Source property. Defined Values: IVIRFSIGGEN_VAL_PULSE_TRIGGER_SOURCE_INTERNAL - No external trigger is used. The pulse period is specified by the IviRFSigGen>>Pulse Generator>>Pulse Internal Trigger Period property. IVIRFSIGGEN_VAL_PULSE_TRIGGER_SOURCE_EXTERNAL - The pulse is started with a trigger after the delay time specified by the IviRFSigGen>>Pulse Generator>>Pulse External Trigger Delay property. Default Value: IVIRFSIGGEN_VAL_PULSE_TRIGGER_SOURCE_INTERNAL

    datatype_icon

    instrument handle out

    The instrument handle that you obtain from the IviRFSigGen Initialize Node or IviRFSigGen Initialize With Options Node. The handle identifies a particular instrument session.

    Default: None

    datatype_icon

    error out

    Error information.

    The node produces this output according to standard error behavior.

    Standard Error Behavior

    Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.

    error in does not contain an error error in contains an error
    If no error occurred before the node runs, the node begins execution normally.

    If no error occurs while the node runs, it returns no error. If an error does occur while the node runs, it returns that error information as error out.

    If an error occurred before the node runs, the node does not execute. Instead, it returns the error in value as error out.
    datatype_icon

    error in

    Error conditions that occur before this node runs.

    The node responds to this input according to standard error behavior.

    Standard Error Behavior

    Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.

    error in does not contain an error error in contains an error
    If no error occurred before the node runs, the node begins execution normally.

    If no error occurs while the node runs, it returns no error. If an error does occur while the node runs, it returns that error information as error out.

    If an error occurred before the node runs, the node does not execute. Instead, it returns the error in value as error out.

    Default: No error

    datatype_icon

    instrument handle

    The instrument handle that you obtain from the IviRFSigGen Initialize Node or IviRFSigGen Initialize With Options Node. The handle identifies a particular instrument session.

    Default: None