Table Of Contents

IviPwrMeter Send Software Trigger [SWT] (G Dataflow)

Version:
    Last Modified: October 24, 2017

    Sends a command to trigger the power meter. Call this node if you pass IVIPWRMETER_VAL_SOFTWARE_TRIG for the IviPwrMeter>>Trigger>>Trigger Source [TRG] property or the Trigger Source parameter of the IviPwrMeter Configure Trigger Source [TRG] node.

    spd-note-note
    Note  

    If the IviPwrMeter>>Trigger>>Trigger Source [TRG] is not set to the IVIPWRMETER_VAL_SOFTWARE_TRIG value, this node returns a Trigger Not Software (0xBFFA1001) error.

    spd-note-note
    Note  

    This node does not check the instrument status. Typically, you call this node only in a sequence of calls to other low-level driver nodes. The sequence performs one operation. You use the low-level nodes to optimize one or more aspects of interaction with the instrument. If you want to check the instrument status, call the IviPwrMeter Error-Query node at the conclusion of the sequence.

    connector_pane_image
    datatype_icon

    instrument handle out

    Instrument handle that you obtain from IviPwrMeter Initialize or IviPwrMeter Initialize With Options. The handle identifies a particular instrument session.

    Default: None

    datatype_icon

    error out

    Error information.

    The node produces this output according to standard error behavior.

    Standard Error Behavior

    Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.

    error in does not contain an error error in contains an error
    If no error occurred before the node runs, the node begins execution normally.

    If no error occurs while the node runs, it returns no error. If an error does occur while the node runs, it returns that error information as error out.

    If an error occurred before the node runs, the node does not execute. Instead, it returns the error in value as error out.
    datatype_icon

    error in

    Error conditions that occur before this node runs.

    The node responds to this input according to standard error behavior.

    Standard Error Behavior

    Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.

    error in does not contain an error error in contains an error
    If no error occurred before the node runs, the node begins execution normally.

    If no error occurs while the node runs, it returns no error. If an error does occur while the node runs, it returns that error information as error out.

    If an error occurred before the node runs, the node does not execute. Instead, it returns the error in value as error out.

    Default: No error

    datatype_icon

    instrument handle

    Instrument handle that you obtain from IviPwrMeter Initialize or IviPwrMeter Initialize With Options. The handle identifies a particular instrument session.

    Default: None

    Where This Node Can Run:

    Desktop OS: Windows

    FPGA: Not supported

    Web Server: Not supported in VIs that run in a web application


    Recently Viewed Topics