Table Of Contents

IviDmm Configure Thermocouple [TC] (G Dataflow)

Version:
    Last Modified: October 24, 2017

    Configures the thermocouple type and the reference junction type of the thermocouple for DMMs that take temperature measurements using a thermocouple transducer type.

    This node affects the behavior of the instrument only if the IviDmm>Temperature Measurements>Transducer Type [TMP] property is set to IVIDMM_VAL_THERMOCOUPLE.

    connector_pane_image
    datatype_icon

    ref junc type

    Pass the type of reference junction to be used in the reference junction compensation of a thermocouple measurement. The driver uses this value to set the IviDmm>Temperature Measurements>Thermocouple>Reference Junction Type [TC] property.

    Defined Values

    Default: IVIDMM_VAL_TEMP_REF_JUNC_INTERNAL

    datatype_icon

    thermocouple type

    Pass the type of thermocouple used to measure the temperature. The driver uses this value to set the IviDmm>Temperature Measurements>Thermocouple>Thermocouple Type [TC] property.

    Defined Values

    IVIDMM_VAL_TEMP_TC_B IVIDMM_VAL_TEMP_TC_C
    IVIDMM_VAL_TEMP_TC_D IVIDMM_VAL_TEMP_TC_E
    IVIDMM_VAL_TEMP_TC_J IVIDMM_VAL_TEMP_TC_K
    IVIDMM_VAL_TEMP_TC_N IVIDMM_VAL_TEMP_TC_R
    IVIDMM_VAL_TEMP_TC_S IVIDMM_VAL_TEMP_TC_T
    IVIDMM_VAL_TEMP_TC_U IVIDMM_VAL_TEMP_TC_V

    Default: IVIDMM_VAL_TEMP_TC_B

    datatype_icon

    error out

    Error information.

    The node produces this output according to standard error behavior.

    Standard Error Behavior

    Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.

    error in does not contain an error error in contains an error
    If no error occurred before the node runs, the node begins execution normally.

    If no error occurs while the node runs, it returns no error. If an error does occur while the node runs, it returns that error information as error out.

    If an error occurred before the node runs, the node does not execute. Instead, it returns the error in value as error out.
    datatype_icon

    error in

    Error conditions that occur before this node runs.

    The node responds to this input according to standard error behavior.

    Standard Error Behavior

    Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.

    error in does not contain an error error in contains an error
    If no error occurred before the node runs, the node begins execution normally.

    If no error occurs while the node runs, it returns no error. If an error does occur while the node runs, it returns that error information as error out.

    If an error occurred before the node runs, the node does not execute. Instead, it returns the error in value as error out.

    Default: No error

    datatype_icon

    instrument handle out

    The instrument handle that you obtain from the IviDmm Initialize Node. The handle identifies a particular instrument session.

    Default: None

    datatype_icon

    instrument handle

    The instrument handle that you obtain from the IviDmm Initialize Node. The handle identifies a particular instrument session.

    Default: None

    Extension Group

    This node is part of the IviDmmThermocouple [TC] extension group.