Table Of Contents

IviDigitizer Configure Acquisition (G Dataflow)

Version:
    Last Modified: October 24, 2017

    Configures the most commonly configured properties of the digitizer acquisition sub-system: the IviDigitizer Num Records to Acquire, IviDigitizer Record Size, and IviDigitizer Sample Rate properties.

    connector_pane_image
    datatype_icon

    instrument handle

    The instrument handle that you obtain from the IviDigitizer Initialize Node or IviDigitizer Initialize With Options Node. The handle identifies a particular instrument session.

    Default: None

    datatype_icon

    error in

    Error conditions that occur before this node runs.

    The node responds to this input according to standard error behavior.

    Standard Error Behavior

    Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.

    error in does not contain an error error in contains an error
    If no error occurred before the node runs, the node begins execution normally.

    If no error occurs while the node runs, it returns no error. If an error does occur while the node runs, it returns that error information as error out.

    If an error occurred before the node runs, the node does not execute. Instead, it returns the error in value as error out.

    Default: No error

    datatype_icon

    error out

    Error information.

    The node produces this output according to standard error behavior.

    Standard Error Behavior

    Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.

    error in does not contain an error error in contains an error
    If no error occurred before the node runs, the node begins execution normally.

    If no error occurs while the node runs, it returns no error. If an error does occur while the node runs, it returns that error information as error out.

    If an error occurred before the node runs, the node does not execute. Instead, it returns the error in value as error out.
    datatype_icon

    instrument handle out

    The instrument handle that you obtain from the IviDigitizer Initialize Node or IviDigitizer Initialize With Options Node. The handle identifies a particular instrument session.

    Default: None

    datatype_icon

    Record Size (256)

    Specifies the number of samples in each record. This value sets the IviDigitizer Record Size property. Default Value: 256

    datatype_icon

    Number of Records (1)

    Specifies the number of records in the acquisition. This value sets the IviDigitizer Num Records to Acquire property. Default Value: 1

    datatype_icon

    Sample Rate (1.0e5)

    Specifies the sample rate in samples per second. This value sets the IviDigitizer Sample Rate property. Default Value: 1.0e5

    Where This Node Can Run:

    Desktop OS: Windows

    FPGA: Not supported

    Web Server: Not supported in VIs that run in a web application