    Obtains a measurement based on the preset configuration and returns the measurement value.

    The measurement is from a measurement that was previously initiated.

    Use IviCounter Initiate to start the previously configured measurement. Use IviCounter Status to determine when the measurement is complete.

    You can call IviCounter Read instead of IviCounter Initiate. IviCounter Read starts a measurement. It then waits for the measurement to complete, obtains the measured value, and returns the measured value. You call this node separately for any other measurements that you want to obtain on a specific channel.

    spd-note-note
    Note  

    This node does not check the instrument status.

    spd-note-note
    Note  

    Typically, you call this node only in a sequence of calls to other low-level driver nodes. The sequence performs one operation. You use the low-level nodes to optimize one or more aspects of interaction with the instrument. If you want to check the instrument status, call IviCounter Error-Query at the conclusion of the sequence.

    connector_pane_image
    datatype_icon

    instrument handle

    The instrument handle that you obtain from IviACPwr Initialize or IviACPwr Initialize With Options. The handle identifies a particular instrument session.

    Default: None

    datatype_icon

    error in

    Error conditions that occur before this node runs.

    The node responds to this input according to standard error behavior.

    Standard Error Behavior

    Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.

    error in does not contain an error error in contains an error
    If no error occurred before the node runs, the node begins execution normally.

    If no error occurs while the node runs, it returns no error. If an error does occur while the node runs, it returns that error information as error out.

    If an error occurred before the node runs, the node does not execute. Instead, it returns the error in value as error out.

    Default: No error

    datatype_icon

    instrument handle out

    The instrument handle that you obtain from IviACPwr Initialize or IviACPwr Initialize With Options.

    datatype_icon

    error out

    Error information.

    The node produces this output according to standard error behavior.

    Standard Error Behavior

    Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.

    error in does not contain an error error in contains an error
    If no error occurred before the node runs, the node begins execution normally.

    If no error occurs while the node runs, it returns no error. If an error does occur while the node runs, it returns that error information as error out.

    If an error occurred before the node runs, the node does not execute. Instead, it returns the error in value as error out.
    datatype_icon

    measurement

    Returns the measured value.

    The units depend on the Measurement Function you select as shown below.

    Measurement Function Units
    Rise Time seconds
    Fall Time seconds
    Frequency hertz
    Frequency Ratio units
    PRF hertz
    Period seconds
    Phase degrees
    Negative seconds
    Width Positive seconds
    Cycle Negative percent
    Duty Cycle Positive percent
    Time Interval seconds