From 12:00 PM - 4:00 PM CST on Thursday, October 18, ni.com will be undergoing system upgrades that may result in temporary service interruption.

We appreciate your patience as we improve our online experience.

Table Of Contents

IVI Counter Configuration Nodes (G Dataflow)

Version:
    Last Modified: October 23, 2017

    node_icon
    Configures the IviCounter Channel Filter Enabled property for a particular channel.
    node_icon
    Configures the IviCounter Channel Level and IviCounter Hysteresis properties for a particular channel.
    node_icon
    Configures the IviCounter Channel Slope property for a particular channel.
    node_icon
    Configures the most commonly configured properties of the counter channel: IviCounter Impedance, IviCounter Coupling, and IviCounter Attenuation.
    node_icon
    Configures the counter for a continuous totalize measurement on a particular channel.
    node_icon
    Configures the IviCounter Duty Cycle Estimate and IviCounter Duty Cycle Resolution properties for a duty cycle measurement.
    node_icon
    Configures the IviCounter Edge Time Estimate and IviCounter Edge Time Resolution properties for an edge time measurement.
    node_icon
    Configures the IviCounter Edge Time Reference Type, IviCounter Edge Time Estimate, IviCounter Edge Time Resolution, IviCounter Edge Time High Reference Level, and IviCounter Edge Time Low Reference Level properties for an edge time measurement. If the channel slope is positive a rise-time measurement is performed, if the channel slope is negative, a fall-time measurement is performed.
    node_icon
    Configures the IviCounter External Start Arm Source, IviCounter External Start Arm Level, IviCounter External Start Arm Slope, and IviCounter External Start Arm Delay properties.
    node_icon
    Configures the IviCounter External Stop Arm Source, IviCounter External Stop Arm Level, IviCounter External Stop Arm Slope and IviCounter External Stop Arm Delay properties.
    node_icon
    Configures the IviCounter Frequency Estimate and IviCounter Frequency Resolution properties for a frequency measurement for a particular channel.
    node_icon
    Configures the IviCounter Frequency Ratio Estimate and IviCounter Frequency Ratio Resolution properties for a frequency ratio measurement.
    node_icon
    Configures the IviCounter Frequency Aperture Time property for a frequency measurement.
    node_icon
    Allows the instrument to automatically determine the best estimate and resolution for the selected channel. This node sets the IviCounter Frequency Estimate Auto property to TRUE, the IviCounter Frequency Resolution Auto property to TRUE, and the IviCounter Frequency Aperture Time property is set to indicate the aperture time selected by the instrument.
    node_icon
    Configures the IviCounter Gated Totalized Channel, IviCounter Gated Totalized Gate Source, and IviCounter Gated Totalized Gate Slope properties for a gated totalize measurement.
    node_icon
    Configures the IviCounter Period Aperture Time property for a period measurement.
    node_icon
    Configures the IviCounter Period Estimate and IviCounter Period Resolution properties for a period measurement.
    node_icon
    Configures the IviCounter Phase Frequency Estimate and IviCounter Phase Resolution properties for a phase measurement.
    node_icon
    Configures the IviCounter Pulse Width Estimate and IviCounter Pulse Width Resolution properties for a pulse width measurement.
    node_icon
    Configures the type of start arm to immediate or external.
    node_icon
    Configures the type of stop arm.
    node_icon
    Configures the IviCounter Time Interval Estimate and IviCounter Time Interval Resolution properties for a time interval measurement.
    node_icon
    Configures the IviCounter Timed Totalize Channel and IviCounter Timed Totalize Gate Time properties for a timed totalize measurement.