Table Of Contents

NI-5772 Specifications

Version:
    Last Modified: April 12, 2017

    This document lists specifications for the NI-5772. All specifications are subject to change without notice.

    spd-note-caution
    Caution  

    The protection provided by the NI-5772 can be impaired if it is used in a manner not described in this document.

    spd-note-caution
    Caution  

    To avoid permanent damage to the NI-5772, disconnect all signals connected to the NI-5772 before powering down the module, and only connect signals after the module has been powered on by the FlexRIO FPGA module or the Controller for FlexRIO.

    Specifications are subject to change without notice. For the most recent device specifications, visit ni.com/manuals.

    Definitions

    Warranted specifications describe the performance of a model under stated operating conditions and are covered by the model warranty.

    Characteristics describe values that are relevant to the use of the model under stated operating conditions but are not covered by the model warranty.

    • Typical specifications describe the expected performance met by a majority of the models.
    • Nominal specifications describe parameters and attributes that may be useful in operation.

    Specifications are Typical unless otherwise noted.

    Analog Input (AI 0 and AI 1)

    General Characteristics

    Number of channels

    Two

    Connector type

    SMA

    Input type

    Single-ended, simultaneously sampled or time-interleaved sampled (TIS)

    Input impedance

    50 Ω, per connector

    Input coupling

    AC (-01L version); DC (-02L version)

    Digital data resolution

    12-bit, signed, binary data[1]

    ADC part number

    ADC12D800RF[2]

    Absolute maximum voltage

    ±10 VDC, +21 dBm (7.1 Vpk-pk)

    Typical Specifications

    All specifications were tested in TIS Disabled mode unless otherwise specified.

    DC offset

    AC-coupled

    ±4.3 mV

    DC-coupled

    ±6.5 mV

    Full-scale input

    +10 dBm (2 Vpk-pk) or +16 dBm (4 Vpk-pk)[3]

    Gain error

    AC-coupled

    ±2.0% full scale range (FSR)

    DC-coupled

    ±6.5% full scale range (FSR)

    Table 1. Analog Input Jitter
    Integration Range Internal Free-Running Internal Locked to IOModSyncCLK
    10 Hz to 10 MHz 580 fs rms 770 fs rms
    100 Hz to 10 MHz 95 fs rms 175 fs rms
    10 kHz to 10 MHz 85 fs rms 85 fs rms
    Table 2. Average Noise Density
    nV/√Hz dBm/Hz dBFS/Hz
    AC-coupled 30 -137.5 -147.5
    DC-coupled 33 -136.6 -146.6
    Table 3. AC Low Cut-Off Frequency (Referenced to Amplitude at 10 MHz)
    -3 dB -1 dB
    AC-coupled 110 kHz 240 kHz
    DC-coupled 0 kHz 0 kHz
    Table 4. Bandwidth And Spectral Performance Summary
    Mode Coupling Bandwidth (-3 dB) Bandwidth (-1 dB) SNR (dB)¹ SFDR (dBc)¹ THD (dBc)¹ ENOB (bits)¹
    TIS Disabled (default) AC-coupled 2.27 GHz 780 MHz 58 -65 -63 9.2
    DC-coupled 358 MHz 320 MHz 57 -65 -64 9.1
    TIS Enabled, Muxed to CH 0 AC-coupled 780 MHz 450 MHz 57 -63 -63 9.0
    DC-coupled 356 MHz 312 MHz 57 -63 -65 9.0
    TIS Enabled, Muxed to CH 1 AC-coupled 780 MHz 450 MHz 57 -63 -63 9.0
    DC-coupled 356 MHz 312 MHz 57 -63 -65 9.0
    TIS Enabled, Non-Muxed AC-coupled 2.0 GHz 690 MHz 56 -60 -63 8.9
    DC-coupled N/A N/A N/A N/A N/A N/A
    ¹Measured using a -1 dBFS signal at 187 MHz.

    Analog Input Impedance

    Analog Input Impedance

    Figure 1. Analog Input Return Loss (Multiple Channels Overlaid)
    Figure 2. Analog Input VSWR (Multiple Channels Overlaid)

    Frequency Response

    spd-note-note
    Note  

    Referenced at 10 MHz using +9 dBm.

    Figure 3. AC Low Frequency Response (Referenced to Amplitude at 10 MHz)
    Figure 4. High Frequency Response (Referenced to Amplitude at 10 MHz)
    Figure 5. DC Bandwidth (Referenced to Amplitude at 10 MHz)
    Figure 6. DC Bandwidth Flatness (Referenced to Amplitude at 10 MHz)

    Spectral Measurements

    Figure 7. Noise Density
    Figure 8. One-Tone Spectral Measurement (TIS Disabled, 187 MHz, -1 dBFS)
    Figure 9. Two-Tone Spectral Measurement (TIS Multiplexed Mode, 182k Samples, 10 Averages)

    Analog Input Total Phase Noise

    Figure 10. Analog Input Total Phase Noise (353 MHz, -1 dBFS carrier)

    *Uses a 10 MHz Wenzel OCXO (P/N: 501-04609A) as the reference signal.

    Crosstalk

    Figure 11. AI Crosstalk (Aggressor at -1 dBFS, Victim Terminated to 50 Ω) [4]
    Figure 12. AI Crosstalk (Aggressor at -1 dBFS, Victim Terminated to 50 Ω)

    Internal Sample Clock

    General Characteristics

    PLL part number

    HMC703[5]

    Oscillator type

    VCO

    Frequency

    800 MHz ± 25 ppm

    Stability

    ±5 ppm

    Sampling jitter[6]

    90 fs rms

    CLK IN

    General Characteristics

    Number of channels

    1, single-ended

    Connector type

    SMA

    Frequency range

    400 MHz to 800 MHz

    Input impedance

    50 Ω

    Input coupling

    AC

    Input voltage range

    +2 dBm (800 mVpk-pk) to +16 dBm (4 Vpk-pk)

    Absolute maximum voltage

    ±30 VDC, +21 dBm (7.1 Vpk-pk)

    Duty cycle

    30% to 70%

    REF IN

    REF IN General Characteristics

    Number of channels

    1, single-ended

    Connector type

    SMA

    Frequency

    10 MHz

    Input impedance

    50 Ω

    Input coupling

    AC

    Input voltage range

    +2 dBm (800 mVpk-pk) to 16 dBm (4 Vpk-pk)

    Absolute maximum voltage

    ±30 VDC, +21 dBm (7.1 Vpk-pk)

    Duty cycle

    30% to 70%

    TRIG (I/O)

    TRIG General Characteristics

    Number of channels

    1, single-ended

    Connector type

    SMA

    Coupling

    DC

    Impedance

    Input

    20 kΩ

    Output

    50 Ω

    Logic level

    3.3V CMOS

    Voltage

    VIH_MIN

    2 V

    VIL_MAX

    0.8 V

    VOH_MIN (unloaded)

    3.1 V

    VOL_MAX (unloaded)

    0.2 V

    Absolute maximum voltage

    ±20 VDC, +21 dBm (7.1 Vpk-pk)

    Current

    IOH_MAX

    12 mA

    IOL_MAX

    -12 mA

    AUX I/O (Port 0 DIO <0..3>, Port 1 DIO <0..3>, and PFI <0..3>)

    Number of channels

    12 bidirectional (8 DIO and 4 PFI)

    Connector type

    HDMI

    Interface standard

    3.3 V LVCMOS

    Interface logic

    Maximum VIL

    0.8 V

    Minimum VIH

    2.0 V

    Maximum VOL

    0.4 V

    Minimum VOH

    2.7 V

    Maximum VOH

    3.6 V

    Zout

    50 Ω ±20%

    Iout (DC)

    ±2 mA

    Pull-down resistor

    150 kΩ

    Recommended operating voltage

    -0.3 V to 3.6 V

    Overvoltage protection

    ±10 V

    Maximum toggle frequency

    6.6 MHz

    +5 V maximum power

    10 mA

    +5 V voltage tolerance

    4 V to 5 V

    EEPROM Map

    spd-note-caution
    Caution  

    Only write to User Space. Writing to any other offset may cause the NI-5772 to stop functioning.

    Table 5. EEPROM Map
    Byte Address Size (Bytes) Field Name
    0x0 2 Vendor ID
    0x2 2 Product ID
    0x4 4 Serial Number
    0x8 116 Reserved
    0x7C 132 User Space

    Power

    Total power, typical operation

    5.1 W

    Physical

    Dimensions

    12.9 x 2.0 x 12.1 cm (5.1 x 0.8 x 4.7 in.)

    Weight

    660 g (23.3 oz)

    Front panel connectors

    5 SMA connectors and one HDMI connector

    Environment

    Maximum altitude

    2,000 m (800 mbar) (at 25 °C ambient temperature)

    Pollution Degree

    2

    Indoor use only.

    Operating Environment

    Ambient temperature range

    0 °C to 55 °C (Tested in accordance with IEC 60068-2-1 and IEC 60068-2-2. Meets MIL-PRF-28800F Class 3 low temperature limit and MIL-PRF-28800F Class 2 high temperature limit.)

    Relative humidity range

    10% to 90%, noncondensing (Tested in accordance with IEC 60068-2-56.)

    Storage Environment

    Ambient temperature range

    -20 °C to 70 °C (Tested in accordance with IEC 60068-2-1 and IEC 60068-2-2. Meets MIL-PRF-28800F Class 3 limits.)

    Relative humidity range

    5% to 95%, noncondensing (Tested in accordance with IEC 60068-2-56.)

    Shock and Vibration

    Operating shock

    30 g peak, half-sine, 11 ms pulse (Tested in accordance with IEC 60068-2-27. Meets MIL-PRF-28800F Class 2 limits.)

    Random vibration

    Operating

    5 Hz to 500 Hz, 0.3 grms (Tested in accordance with IEC 60068-2-64.)

    Nonoperating

    5 Hz to 500 Hz, 2.4 grms (Tested in accordance with IEC 60068-2-64. Test profile exceeds the requirements of MIL-PRF-28800F, Class 3.)

    Compliance and Certifications

    Safety

    This product is designed to meet the requirements of the following electrical equipment safety standards for measurement, control, and laboratory use:

    • IEC 61010-1, EN 61010-1
    • UL 61010-1, CSA C22.2 No. 61010-1
    spd-note-note
    Note  

    For UL and other safety certifications, refer to the product label or the Online Product Certification section.

    Electromagnetic Compatibility

    This product meets the requirements of the following EMC standards for electrical equipment for measurement, control, and laboratory use:
    • EN 61326-1 (IEC 61326-1): Class A emissions; Basic immunity
    • EN 55011 (CISPR 11): Group 1, Class A emissions
    • EN 55022 (CISPR 22): Class A emissions
    • EN 55024 (CISPR 24): Immunity
    • AS/NZS CISPR 11: Group 1, Class A emissions
    • AS/NZS CISPR 22: Class A emissions
    • FCC 47 CFR Part 15B: Class A emissions
    • ICES-001: Class A emissions
    spd-note-note
    Note  

    In the United States (per FCC 47 CFR), Class A equipment is intended for use in commercial, light-industrial, and heavy-industrial locations. In Europe, Canada, Australia, and New Zealand (per CISPR 11), Class A equipment is intended for use only in heavy-industrial locations.

    spd-note-note
    Note  

    Group 1 equipment (per CISPR 11) is any industrial, scientific, or medical equipment that does not intentionally generate radio frequency energy for the treatment of material or inspection/analysis purposes.

    spd-note-note
    Note  

    For EMC declarations, certifications, and additional information, refer to the Online Product Certification section.

    CE Compliance

    This product meets the essential requirements of applicable European Directives, as follows:

    • 2014/35/EU; Low-Voltage Directive (safety)
    • 2014/30/EU; Electromagnetic Compatibility Directive (EMC)

    Online Product Certification

    Refer to the product Declaration of Conformity (DoC) for additional regulatory compliance information. To obtain product certifications and the DoC for this product, visit ni.com/certification, search by model number or product line, and click the appropriate link in the Certification column.

    Environmental Management

    NI is committed to designing and manufacturing products in an environmentally responsible manner. NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environment and to NI customers.

    For additional environmental information, refer to the Minimize Our Environmental Impact web page at ni.com/environment. This page contains the environmental regulations and directives with which NI complies, as well as other environmental information not included in this document.

    Waste Electrical and Electronic Equipment (WEEE)

    spd-note-weee
    EU Customers  

    At the end of the product life cycle, all NI products must be disposed of according to local laws and regulations. For more information about how to recycle NI products in your region, visit ni.com/environment/weee.

    电子信息产品污染控制管理办法(中国RoHS)

    spd-note-china-rohs
    中国客户  

    National Instruments符合中国电子信息产品中限制使用某些有害物质指令(RoHS)。关于National Instruments中国RoHS合规性信息,请登录 ni.com/environment/rohs_china。(For information about China RoHS compliance, go to ni.com/environment/rohs_china.)

    Worldwide Support and Services

    The NI website is your complete resource for technical support. At ni.com/support, you have access to everything from troubleshooting and application development self-help resources to email and phone assistance from NI Application Engineers.

    Visit ni.com/services for NI Factory Installation Services, repairs, extended warranty, and other services.

    Visit ni.com/register to register your NI product. Product registration facilitates technical support and ensures that you receive important information updates from NI.

    A Declaration of Conformity (DoC) is our claim of compliance with the Council of the European Communities using the manufacturer’s declaration of conformity. This system affords the user protection for electromagnetic compatibility (EMC) and product safety. You can obtain the DoC for your product by visiting ni.com/certification. If your product supports calibration, you can obtain the calibration certificate for your product at ni.com/calibration.

    NI corporate headquarters is located at 11500 North Mopac Expressway, Austin, Texas, 78759-3504. NI also has offices located around the world. For telephone support in the United States, create your service request at ni.com/support or dial 1 866 ASK MYNI (275 6964). For telephone support outside the United States, visit the Worldwide Offices section of ni.com/niglobal to access the branch office websites, which provide up-to-date contact information, support phone numbers, email addresses, and current events.

    • 1 Data is accessed using an I16 data type (left-justified).
    • 2 For additional information about the ADC within your device, use the listed part number to locate the appropriate Texas Instruments data sheet at www.ti.com.
    • 3 Available in the AC-coupled version and in TIS Enabled, Non-Multiplexed sampling mode only.
    • 4 AC-coupled version only.
    • 5 For additional information about the HMC703, refer to the Hittite data sheet at www.hittite.com.
    • 6 Integrated from 100 Hz to 1,600 MHz.