    Reads data from a .tdms file.

    Copyright: (c) 2016 National Instruments. All rights reserved.

    connector_pane_image
    datatype_icon

    count

    Maximum number of data elements to read for each channel.

    Default: -1 — Causes this node to read all available elements.

    datatype_icon

    offset

    Number of data elements into the .tdms file at which this node begins to read.

    Default: 0

    datatype_icon

    tdms file

    A reference to a .tdms file. Use the TDMS Open node to obtain the reference.

    datatype_icon

    group name in

    Channel group on which to perform the operation.

    Reading Behavior When group name in Is Not Wired

    If you do not wire data to group name in, this node reads data from the current group in the file. The current group is either the first group in the file when you run this node for the first time or the nth group at the nth cycle when you run this node continuously for multiple cycles. The order that this node reads groups is the same order that the TDMS List Contents node returns groups. If this node attempts to run after reaching the last group, you receive an end of file error.

    spd-note-note
    Note  

    The TDMS List Contents node and the TDMS Get Properties node reset the current group to the first group in the file. Resetting the current group to the first group in the file impacts the group read by the next TDMS Read node when you do not wire group name in.

    datatype_icon

    channel name(s) in

    Channel or channels to read data from.

    channel name(s) in accepts a string or a 1D array of strings. The data type varies according to the data you wire to data type.

    Determining the Data Type of channel name(s) in

    The following table shows how the data type of channel name(s) in varies according to the data you wire to data type.

    data type channel name(s) in
    • Analog waveform
    • 1D array of:
      • Signed or unsigned integers
      • Floating-point numbers
      • Timestamps
      • Booleans
      • Alphanumeric strings that do not contain null characters
    String
    • Digital waveform
    • Digital table
    • 1D array of analog waveforms
    • 2D array of:
      • Signed or unsigned integers
      • Floating-point numbers
      • Timestamps
      • Booleans
      • Alphanumeric strings that do not contain null characters
    1D Array of Strings

    Reading Behavior When channel name(s) in Is Not Wired

    If you do not wire data to channel name(s) in, this node reads data from all channels under the same group and returns data channels in the same order as they exist in the .tdms file.

    Reading Compressed Digital Data

    If you load a complete file or group that contains compressed digital data, this node automatically inserts the compression channel name in the channel name(s) in array. If you load a subset of a file or group that contains compressed digital data, you must enter the name of the compression channel as the first entry in the channel name(s) in array.

    datatype_icon

    error in

    Error conditions that occur before this node runs.

    The node responds to this input according to standard error behavior.

    Standard Error Behavior

    Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.

    error in does not contain an error error in contains an error
    If no error occurred before the node runs, the node begins execution normally.

    If no error occurs while the node runs, it returns no error. If an error does occur while the node runs, it returns that error information as error out.

    If an error occurred before the node runs, the node does not execute. Instead, it returns the error in value as error out.

    Default: No error

    datatype_icon

    data type

    The type of data you want the node to return.

    Acceptable Data Types

    This input accepts the following data types:

    • Analog waveform or a 1D array of analog waveforms
    • Digital waveform
    • Digital table
    • 1D or 2D array of:
      • Signed or unsigned integers
      • Floating-point numbers, including the following specific data types:
        • Single-precision and double-precision floating-point numbers
        • Complex single-precision and double-precision floating-point numbers
        • Extended-precision floating-point numbers
      • Timestamps
      • Booleans
      • Alphanumeric strings that do not contain null characters
    datatype_icon

    return channels in file order

    A Boolean specifying whether the node returns data channels in the same order as they exist in the .tdms file.

    TRUE Return data channels in the same order as they exist in the .tdms file.
    FALSE Return data channels in the same order as you specify in channel name(s) in.

    Default: FALSE

    datatype_icon

    tdms file out

    A reference to the .tdms file.

    datatype_icon

    group name out

    Channel group on which you performed the operation.

    datatype_icon

    channel name(s) out

    Channel or channels on which you performed the operation.

    datatype_icon

    data

    Data that the node read from the .tdms file.

    If data has scaling information, the node automatically scales the data.

    datatype_icon

    error out

    Error information.

    The node produces this output according to standard error behavior.

    Standard Error Behavior

    Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.

    error in does not contain an error error in contains an error
    If no error occurred before the node runs, the node begins execution normally.

    If no error occurs while the node runs, it returns no error. If an error does occur while the node runs, it returns that error information as error out.

    If an error occurred before the node runs, the node does not execute. Instead, it returns the error in value as error out.
    datatype_icon

    end of file?

    A Boolean that indicates whether the node has reached the end of the file.

    TRUE The node has reached the end of the file.
    FALSE The node has not reached the end of the file while reading data.

    Where This Node Can Run:

    Desktop OS: Windows

    FPGA: DAQExpress does not support FPGA devices


    Recently Viewed Topics