Table Of Contents

PCI-8513 Specifications

Version:
    Last Modified: February 8, 2019

    This document lists specifications for the PCI-8513 1-port and 2-port software-selectable/FD CAN interface device.

    Definitions

    Warranted specifications describe the performance of a model under stated operating conditions and are covered by the model warranty.

    Characteristics describe values that are relevant to the use of the model under stated operating conditions but are not covered by the model warranty.

    • Typical specifications describe the performance met by a majority of models.
    • Nominal specifications describe an attribute that is based on design, conformance testing, or supplemental testing.

    Specifications are Typical unless otherwise noted.

    Conditions

    Specifications are typical at 0 °C to 55 °C unless otherwise noted.

    Power Requirements

    +5 VDC (±5%)

    640 mA

    +3.3 VDC (±5%)

    940 mA

    Physical

    Dimensions and Weight

    Dimensions

    10.67 cm x 16.76 cm (4.2 in. x 6.6 in.)

    Weight

    1 port

    98 g (3.5 oz.)

    2 port

    102 g (3.6 oz.)

    RTSI/Front Panel Sync Connectors

    Trigger lines

    7 input/output

    Clock lines

    1 input/output

    Front panel sync connectors

    2 input/output

    I/O compatibility

    TTL

    Power-on state

    Input (High-Z)

    Response

    Rising edge triggers

    Physical Characteristics

    CAN Physical Layer

    High-Speed CAN, Flexible Data Rate

    Transceiver[1]

    NXP TJA1041 or TJA1043

    Max baud rate[2]

    1 Mbps

    Min baud rate

    40 kbps

    CAN_H, CAN_L bus lines voltage

    -27 VDC to +40 VDC

    Low-Speed/Fault-Tolerant CAN

    Transceiver[3]

    NXP TJA1054A or TJA1055T

    Max baud rate

    125 kbps

    Min baud rate

    40 kbps, 10 kbps min for all error modes

    Single Wire, Software-Selectable

    Transceiver[4]

    NXP AU5790 or ON Semiconductor NCV7356 (single wire),

    Max baud rate

    83.3 kbps

    Min baud rate

    33.3 kbps

    Bus Power Required

    8 V to 18 V

    External CAN Transceiver

    The PCI-8513 allows you to connect an optional external transceiver. Refer to the NI-XNET Hardware and Software Help for more information about connecting an external CAN transceiver and configuring NI-XNET hardware to communicate with the custom transceiver.

    Environmental

    Operating Environment

    Ambient temperature

    0 °C to 55 °C

    Relative humidity

    10% to 90% RH, noncondensing

    Maximum altitude

    2,000 m (800 mbar) at 25 °C ambient temperature

    Indoor use only.

    Storage Environment

    Ambient temperature

    -20 to 70 °C (Tested in accordance with IEC-60068-2-1 and IEC-60068-2-2.)

    Relative humidity

    5 to 95% RH, noncondensing (Tested in accordance with IEC-60068-2-56.)

    Pollution Degree (IEC 60664)

    2

    Isolation Voltages

    Port-to-port ground

    Withstand

    500 Vrms verified by a 5 s dielectric withstand test

    Continuous

    60 VDC, Measurement Category I

    Port-to-earth ground

    Withstand

    500 Vrms verified by a 5 s dielectric withstand test

    Continuous

    60 VDC, Measurement Category I

    spd-note-note
    Note  

    This isolation is intended to prevent ground loops.

    Measurement Category I is for measurement performed on circuits not directly connected to the electrical distribution system referred to as MAINS voltage. MAINS is a hazardous live electrical supply system that powers equipment. This category is for measurements of voltages from specially protected secondary circuits. Such voltage measurements include signal levels, special equipment, limited-energy parts of equipment, circuits powered by regulated low-voltage sources, and electronics.

    spd-note-caution
    Caution  

    Do not connect the PCI-8513 to signals or use for measurements within Measurement Categories II, III, or IV.

    spd-note-caution
    Attention  

    Ne connectez pas le PCI-8513 à des signaux et ne l'utilisez pas pour effectuer des mesures dans les catégories de mesure II, III ou IV.

    spd-note-note
    Note  

    Measurement Categories CAT I and CAT O (Other) are equivalent. These test and measurement circuits are not intended for direct connection to the MAINs building installations of Measurement Categories CAT II, CAT III, and CAT IV.

    Safety Compliance Standards

    This device is designed to meet the requirements of the following electrical equipment safety standards for measurement, control, and laboratory use:

    • IEC 61010-1, EN 61010-1
    • UL 61010-1, CSA C22.2 No. 61010-1
    spd-note-note
    Note  

    For UL and other safety certifications, refer to the device label or the Product Certifications and Declarations section.

    Electromagnetic Compatibility

    This product meets the requirements of the following EMC standards for electrical equipment for measurement, control, and laboratory use:

    • EN 61326-1 (IEC 61326-1): Class A emissions; Basic immunity
    • EN 55011 (CISPR 11): Group 1, Class A emissions
    • EN 55022 (CISPR 22): Class A emissions
    • EN 55024 (CISPR 24): Immunity
    • AS/NZS CISPR 11: Group 1, Class A emissions
    • AS/NZS CISPR 22: Class A emissions
    • FCC 47 CFR Part 15B: Class A emissions
    • ICES-001: Class A emissions
    spd-note-note
    Note  

    Group 1 equipment (per CISPR 11) is any industrial, scientific, or medical equipment that does not intentionally generate radio frequency energy for the treatment of material or inspection/analysis purposes.

    spd-note-note
    Note  

    In the United States (per FCC 47 CFR), Class A equipment is intended for use in commercial, light-industrial, and heavy-industrial locations. In Europe, Canada, Australia and New Zealand (per CISPR 11) Class A equipment is intended for use only in heavy-industrial locations.

    spd-note-notice
    Notice  

    For EMC declarations and certifications, and additional information, refer to the Product Certifications and Declarations section.

    CE Compliance

    This product meets the essential requirements of applicable European Directives, as follows:

    • 2014/35/EU; Low-Voltage Directive (safety)
    • 2014/30/EU; Electromagnetic Compatibility Directive (EMC)

    Product Certifications and Declarations

    Refer to the product Declaration of Conformity (DoC) for additional regulatory compliance information. To obtain product certifications and the DoC for NI products, visit ni.com/certification, search by model number or product line, and click the appropriate link in the Certification column.

    Environmental Management

    NI is committed to designing and manufacturing products in an environmentally responsible manner. NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environment and to NI customers.

    For additional environmental information, refer to the Minimize Our Environmental Impact web page at ni.com/environment. This page contains the environmental regulations and directives with which NI complies, as well as other environmental information not included in this document.

    Waste Electrical and Electronic Equipment (WEEE)

    spd-note-weee
    EU Customers  

    At the end of the product life cycle, all NI products must be disposed of according to local laws and regulations. For more information about how to recycle NI products in your region, visit ni.com/environment/weee.

    电子信息产品污染控制管理办法(中国RoHS)

    spd-note-china-rohs
    中国客户  

    National Instruments符合中国电子信息产品中限制使用某些有害物质指令(RoHS)。关于National Instruments中国RoHS合规性信息,请登录 ni.com/environment/rohs_china。(For information about China RoHS compliance, go to ni.com/environment/rohs_china.)

    • 1 PCI-8513 revision F and later use the TJA1043 transceiver for high-speed/FD CAN; previous hardware revisions use the TJA1041 transceiver. To identify your hardware revision, refer to the 19xxxx<rev>-4xL text on the green label in the top left corner on the secondary side of the board; <rev> indicates the hardware revision.
    • 2 The TJA1043 transceiver is CiA certified for baud rates up to 5 Mbps in the CAN FD fast phase, while speeds up to 8 Mbps are possible experimentally. NI-XNET provides a warning when a transceiver is used at higher baud rates than it is certified for. As new CiA-certified transceivers with higher baud rates are released, NI will continue to update the hardware with newer revisions.
    • 3 PCI-8513 revision E and later use the TJA1055T transceiver for low-speed/fault-tolerant CAN; previous hardware revisions use the TJA1054A transceiver. To identify your hardware revision, refer to the 19xxxx<rev>-4xL text on the green label in the top left corner on the secondary side of the board; <rev> indicates the hardware revision.
    • 4 PCI-8513 revision D and later use the ON Semiconductor NCV7356 single-wire transceiver; previous hardware revisions use the NXP AU5790 single-wire transceiver. To identify your hardware revision, refer to the 19xxxx<rev>-4xL text on the green label in the top left corner on the secondary side of the board; <rev> indicates the hardware revision.